Underfloor heating calculator

Pipe length and loop count from floor area and spacing. Set the room and manifold distance — the rest updates as you go.

The room

Floor area20m²

The area to be heated.

Pipe centre spacing
Distance to manifold8m

For the flow and return run — doubled automatically.

Pipe required

149metres

— split across 2 loops to stay under the max run length.

2
loops
75m
avg. loop length
6.7m/m²
pipe density

Illustrative only. Assumes straight parallel runs and a 100m maximum loop length. Real layouts, waste and manifold port count will shift the final figure — confirm before ordering.

Order too little pipe and you're back at the merchant mid-install. Order a wildly generous margin "just in case" and you've tied up cash in coiled pipe that sits in the van for months. This calculator gives a working figure — pipe length and loop count — from floor area and spacing, so you can order close to what you'll actually use.

Spacing sets the pipe run

Tighter spacing means more pipe per square metre and a more even floor temperature — useful in rooms with high heat loss or poor insulation below. Wider spacing uses less pipe and is common around room perimeters or in less demanding spaces. 150mm is the everyday default for most UK living spaces; 100mm shows up in bathrooms and conservatories; 300mm is typically reserved for perimeter runs rather than the main field.

Why the manifold distance is doubled

The figure you enter is the one-way distance from the manifold to the room. Every loop needs a flow pipe going out and a return pipe coming back, so that distance gets counted twice before it's added to the pipe laid across the floor itself. Skip this and the length you order comes up short the moment you start connecting up.

Why loop count matters

Push too much pipe through a single loop and the pressure drop gets high enough that flow suffers at the far end of the run — the room heats unevenly, or the pump can't keep up. This calculator assumes a conservative 100m maximum per loop, splitting the total pipe length across enough loops to stay under that. Actual maximum loop length varies by pipe bore and manufacturer, so check the spec for the pipe and manifold you're actually fitting.

What this doesn't cover

Real rooms aren't perfect rectangles. Bay windows, chimney breasts, awkward corners and the serpentine pattern pipe actually follows all add waste the straight-line formula doesn't capture. Build in a sensible margin for offcuts and bends, and check manifold port count against the number of loops before you commit to an order.

Seen enough? Claim your patch.

TradesInvo captures every enquiry, replies first, and runs it to a booked, quoted, paid job. Early access is five founder slots per postcode — check yours.

Five slots per postcodeFounder pricing, lockedNo card, ~20 seconds
Coming — founding members first: AI that answers the calls you can't. Today it captures every enquiry so you respond first; call answering is on the roadmap.

Figures are illustrative and based on the numbers you enter. TradesInvo is in early access for UK trades.

The operating system for UK trades businesses — lead to invoice in one place.